Projects / Programmes
Computer monitoring of billet reheating in a walking beam furnace
Code |
Science |
Field |
Subfield |
2.04.02 |
Engineering sciences and technologies |
Materials science and technology |
Metallic materials |
Code |
Science |
Field |
T200 |
Technological sciences |
Thermal engineering, applied thermodynamics |
P170 |
Natural sciences and mathematics |
Computer science, numerical analysis, systems, control |
reheating of billets, mathematical model, computer monitoring
Organisations (3)
, Researchers (8)
0206 Institute of Metals and Technology
no. |
Code |
Name and surname |
Research area |
Role |
Period |
No. of publicationsNo. of publications |
1. |
06554 |
PhD Branislav Glogovac |
Energy engineering |
Researcher |
1998 - 2000 |
110 |
1250 SIJ METAL RAVNE podjetje za proizvodnjo plemenitih jekel d.o.o. (Slovene)
no. |
Code |
Name and surname |
Research area |
Role |
Period |
No. of publicationsNo. of publications |
1. |
02770 |
PhD Ferdinand Grešovnik |
Materials science and technology |
Researcher |
1999 - 2000 |
72 |
2. |
00643 |
PhD Henrik Kaker |
Materials science and technology |
Researcher |
2000 |
37 |
3. |
10767 |
Vladimir Perovnik |
Materials science and technology |
Researcher |
1999 - 2000 |
19 |
1555 University of Ljubljana, Faculty of Natural Sciences and Engeneering
no. |
Code |
Name and surname |
Research area |
Role |
Period |
No. of publicationsNo. of publications |
1. |
00733 |
PhD Tomaž Kolenko |
Materials science and technology |
Head |
1998 - 2000 |
133 |
2. |
11624 |
PhD Borut Kosec |
Materials science and technology |
Researcher |
1999 - 2000 |
996 |
3. |
02665 |
PhD Jakob Lamut |
Materials science and technology |
Researcher |
1999 - 2000 |
372 |
4. |
02673 |
PhD Franc Pavlin |
Energy engineering |
Researcher |
1999 - 2000 |
77 |
Abstract
The subject of the project is a computer monitoring of high-grade steel billet reheating so as to fulfill the reheating requirements and to achieve rational use of energy as well as to optimize the furnace atmosphere and consequently lower the skin decarburization of the charge. For establishing the boundary conditions the measurements of performance parameters will be carried out which are not performed in present practice of reheating. The research comprises the acquisition of performance parameters by use of a system for automatic data acquisition, conversion of signals for computer acquistion of process data, building and validation of the simulation model, and visualisation of measured and calculated quantities.